Arrancador suave 25 A, 230 V ac SSC-25
INTRODUCTION
APPLICATIONS
This mains operated soft start power module gives ramp up time of 12 seconds. The device
starts from 10% loading and loads to 100% in 12 seconds. These units are capable of soft
starting loads up to 25A (when mounted on a suitable heatsink)
Suitable for most resistive and inductive loads within voltage and power limitation, such
as heat lamps, fans, pumps and other ac motor loads

Arrancador suave 25 A, 230 V ac SSC-25
FEATURES
No need adjust ramp up time
No need adjust pedestal
Simple wiring
High inrush capability

Arrancador suave 25 A, 230 V ac SSC-25
SPECIFICATIONS
AC system line voltage 110/230V ± 10% Line frequency 50/60Hz
Unit limiting RMS current 25A I²t for fusing 250 A²s
Unit limiting RMS current 26A Isolation voltage 5000V RMS
Minimum operating current 200mA Ramp time 1 to 60 seconds
Unit current consumption 20mA dc Max Pedestal 10 to 50%
Operating temperature -20 to 85°C Storage temperature 0 to 65°C
FUSING:
It is recommended to use semiconductor (fast acting) type fuses or circuit breakers (Semiconductor – MCB) for unit protection.
On initial switch on some loads may need an increased Factor of Safety (F of S) for unit and/or device protection. (See the
SRA Datasheet for further information)
Download product details Including the size,Installation information and product functionality information
Downloads PDF Manufacturers Exporter of SSC-25 Soft Start Control:
Manufacturers Exporter of SSC-25 Soft Start Control(1048)
ssc-25, soft start control, controller, soft start controller

SSC-25 – Arrancador suave 25 A, 230 V ac SSC-25

Arrancador suave 25 A, 230 V ac SSC-25
Módulo de control de arranque suave, SSC-25
Velocidad de rampa ajustable de 1 a 60 segundos
Pedestal ajustable 10-50%
Amortiguador interno
Altos transitorios de entrada
Adecuado para la mayoría de cargas resistivas e inductivas como lámparas caloríficas, ventiladores, bombas y otras cargas de motor a.c.
Tensión de red ac | 240 V ac +/- 10% |
Frecuencia de línea | 50/60Hz |
Corriente nominal de la unidad | 25 A |
Corriente RMS limitadora del Triac | 26 A |
Corriente de funcionamiento (típica) | 20 mA dc |
Tensión de aislamiento | 5000 V rms |
Temperatura de funcionamiento | 0°C a + 65°C |
Accesorios para controladores de potencia
Atributo | Valor |
---|---|
Fase | 1 |
Tensión de Alimentación | 230 V ac |
Corriente Nominal | 25 A |
Tensión Nominal | 230 V |
Temperatura de Funcionamiento Mínima | -20°C |
Temperatura de Funcionamiento Máxima | +85°C |